At LBN Medical we have a large stock, that includes a lot of different probes, also Siemens ultrasound probes. Our experiences staff can help regarding choice of probes, as compatibility with your ultrasound system is crucial.

You can also buy ultrasound probes from Siemens directly on our webshop.

Siemens 4Z1C

IMG_5793

4Z1C


Frequency rate: 
1.5-3.5 MHz 
Description:
It is compatible with SIEMENS ACUSON SC2000 used for cardiac applications.

 

Siemens 9L4

9L4

9L4


Frequency rate: 
 4-9 MHz 
Description:
The probe is compatible with SIEMENS Acuson S2000/S3000/SC2000/Sequoia ultrasound machines. It is used for breast, cerebrovascular, digital, fetal echo, musculosketal, OB/GYN, pediatric abdomen, , pediatric hip, pelvis, penile, tescicle, thyroid, peripheral vascular.

 

Siemens Acuson 4C1

9L4

Acuson 4c1


Frequency rate: 
 1-4 MHz 
Description:
It curved array ultrasound transducer probe. The probe is used with various clinical applicationsfor instance abdominal and OB/GYN and is compatible with the Sequoia Aspen, 128XP-10, Cypress and Sequoia series ultrasound systems.

 

Siemens CW5

IMG_5760

CW5


Frequency rate: 
 5 MHz 
Description:
Doppler pencil non-imaging probe used for cerebrovascular, tescicle, fetal echo, neonatal cardio, periphelar vascular, transcranial applications. It is  compatible with SIEMENS Acuson Antares/ X300/X500/S2000/S3000/G60S/CV70.

 

Siemens P4-2

DSCN4870

P4-2


Frequency rate: 
2-4  MHz 
Description:
This is a Phased Array Transducer compatible wth SIEMENS  X150/ X300/ X500 and G40 ultrasound systems. Used in abdominal and cardiac applications.

 

Siemens PH4-1

PH4-1

PH4-1


Frequency rate: 
 1-4 MHz 
Description:  Phased ArrayTransducer used in adult abdominal, fetal echo, OB/GYN, pelvis and renal applications.

Siemens VF13-5

VF13-5

VF13-5


Frequency rate: 
 5-13 MHz 
Description:  Linear array transducer used for breast, cerebrovascular, digital, emergency medicine, musculoskeletal, superficial musculoskeletal, penile, superficial vascular, tescicle, thyroid, venous. Compatible with SIEMENS Acuson X300/X150/Sonoline G40.

Siemens CH4-1

IMG_7962

CH4-1


Frequency rate: 
1-4 MHz 
Description:  Curved array transducer used for adult abdomen, OB/GYN, fetal echo, pelvis, renal as well as technically dfdicult patients. It is compatible with SIEMENS Acuson Antares.

Siemens EC9-4

IMG_7958

EC9-4


Frequency rate: 
 4-9 MHz 
Description:  Endovacity Transducer used for OB/GYN, endovaginal, prostate, neonatal head applications. It is compatible with SIEMENS G40/G50/ Acuson Antares.

Siemens VF10-5

IMG_7953

VF10-5


Frequency rate: 
5-10 MHz 
Description:  Linear array transducer used for Breast, Thyroid, Testicle, MSK, Orthopedics, Vascular, Venous, Digital, Penile, Cerebral Vascular, Pediatric Hip. It is compatible with SIEMENS X300/X150/ Acuson Antares/G40 ultrasound systems.

Siemens VFX9-4

IMG_7929

VFX9-4


Frequency rate:
4-9 MHz 
Description:  Linear Matrix Array transducer used for testicle, thyroid, breast, penile, peripheral vascular, cerbrovascular, musculoskeletal, orthopedics, pediatric hip, targeted abdominal, pediatric abdomen, targeted OB/GYN, pelvis, and fetal heart applications. It is compatible with Siemens Sonoline Antares.

Siemens 4V1c

DSCN4719

4V1c


Frequency rate:
1-4,5 MHz 
Description:  Vector transducer for transthoracic adult, pediatric echocardiography, stress Echo, coronary artery imaging, contrastagent studies, transcranial. Transducer for the Sequoia 512 and S2000 machines.

Siemens CH5-2

IMG_5771

CH5-2


Frequency rate:
2-5 MHz 
Description:  Curved  transducer used for abdomen, early OB, emegency medicine, fetal echo, OB/GYN, peripheral vascular, renal, urology, venous. Compatible with Siemens Acuson x300/x150/ Sonoline G40S/G40.

Siemens 3V2c

3V2c_01

3V2c


Frequency rate:
1,8-3,6 MHz 
Description:  Vector transducer used for adult cardiac application which is compatible with Siemens Acuson Cypress and Cypress CV ultrasound system.

Siemens 7V3c

7V3c_01

7V3c


Frequency rate: 
5,5-6,4 MHz 
Description:  Vector transducer used for pediatric as well as cardiac applications. The probe is compatible with Siemens Acuson Cypress ultrasound machine.

Siemens 8L5

IMG_7616

8L5
Frequency rate: 5-8 MHz 
Description:  It is linear transducer used for small parts, musculoskeletal, peripheral vascular, extracranial vascular, breast, medium deph arteliar and venous studies. The probe is compatible with Siemens Acuson Sequoia C512/C256 echacardiography systems.

Siemens 4V2

4v2
4V2
Frequency rate:  2,5-4 MHz 
Description:  It is a vector array ultrasound transducer used for abdominal, renal, adult Echo applications. It is compatible with Acuson Sequoia ultrasound systems.

Siemens EC-10C5

EC10C5_01

EC-10C5
Frequency rate: 4-8  MHz 
Description:  It is curved array endocavity ultrasound transducer used for endovacity, prostate, seminal vesicles, urinary bladder, urodynamic studies, transrectal biopsies, endovaginal OB, general GYN. It is compatible with Siemens Acuson Sequoia ultrasound systems.

Siemens 8V5

IMG_7667

8V5

 

 Frequency rate: 5,5-8,5 MHz 
Description:  Neonatal cardiac ultrasound transducer which is compatible with Acuson Sequoia ultrasound systems. It is used for neonatal head, neonatal and pediatric abdominal applications.

Siemens 15L8w

IMG_7656

15L8w

 

 Frequency rate: 8-15 MHz 
Description:  It is broadband, linear array transducer used for pediatric and neonatal superficial imaging, breast, musculoskeletal, testicular, thyroid, superficial vascular applications. It is compatible with Siemens Acuson C512 ultrasound system.

Siemens 8V3

IMG_8627

8V3

 

 Frequency rate: 2,5-8  MHz 
Description:  Vector transducer used for fetal Echo, neonatal Echo, neonatal head, pediatric Echo and pediatric abdomen. It is compatible with Siemens Acuson S2000/S3000/ Acuson Sequoia.

Siemens 10V4

IMG_8621

10V4

 

 Frequency rate: 4-10 MHz 
Description:  Vector array transducer which is used in neonatal echo, neonatal head, pediatric abdomen, pediatric echo, pelvis and renal applications. It is compatible with Siemens Acuson S2000/S3000/ Sequoia 512.

Siemens 4V1

IMG_0791 - Kopi

4V1

 

 Frequency rate: 1-4,5 MHz 
Description:  Vector transducer which is used for abdomen, fetal Echo, OB/GYN, pelvis, renal. It is compatible with Siemens Acuson S2000/ Cypress/ Aspen/Sequoia ultrasound systems.

Siemens 14L5-SP

IMG_6537

14L5-SP

 

 Frequency rate: 5-14 MHz 
Description:  Hockey stick transcuder used for breast , cerebrovascular, , digital, penile, intraoperative abdomen, intraoperative vascular, musculoskeletal, testicle, thyroif imaging applications. It is compatible with Siemens Acuson S2000/S3000 ultrasound systems.

Siemens CH6-2

IMG_6890

CH6-2

 

 Frequency rate: 2-6 MHz 
Description:  Curved Array Transducer used for adult abdomen, pediatric abdomen, OB/GYN, fetal Echo, pelvis, renal, vascular applications. It is compatible with Siemens Acuson Antares ultrasound systems.